Existing Genset / Controller
|
ComAp Retrofit Replacement
|
Gensets with the following configuration and application:
- Standby Generators, Prime, Rental that do NOT parallel with each other or the grid
- Diesel, Natural Gas, Propane fueled engines
- Single phase 120V / 240V through 277V / 480V (347V / 600V CA)
- Analog / Hydro Mechanical Engines
- Electronic (ECU/ECM) engines
- Any emissions Tier (none, Tier 2, 3, 4…..)
Examples include:
- Generac
- Katolight KASSEC (analog / HM hand wired panels)
- KDGC (Basler DGC 2000, 1000, 500 and 2020)
- MTU Onsite Energy
- Kohler – Decision Maker
- Thomson Technologies MEC2 & 20
- MQ
- Baldor
- Paramount
- SIMPOWER
- Frontier
|
Single genset operation
ComAp RT3-MRS16
|
Gensets with the following configuration and application:
- Standby Generators, Prime, Rental that do parallel with each other or the grid
- Diesel, Natural Gas, Propane fueled engines
- Single phase 120V / 240V through 277V / 480V (347V / 600V CA)
- Analog / Hydro Mechanical Engines
- Electronic (ECU/ECM) engines
- Any emissions Tier (none, Tier 2, 3, 4…..)
|
Parallel operation
The ComAp RT3-IG200 or RT3-IG500 is suitable anywhere the RT3-MRS16 fits, but the site needs synchronizing for gen-gen paralleling or gen-mains.
|
Gensets with the following configuration and application:
- Standby Generators, Prime, Rental that do NOT parallel with each other or the grid
- Diesel, Natural Gas, Propane fueled engines
- 1 Ø 120V / 240V through 3Ø 277V / 480V (347V / 600V CA)
- 4160 through 15KV via PT
- Analog/ Hydro Mechanical Engines
Examples include:
- Cummins
- Detector 12
- PCC2100
- Fully authority electornic (FAE) / ECU / ECM controlled
- PCC3100
- Excludes QST30 engine & DFHx
|
Single genset operation
ComAp RC3-MRS16
|
Gensets with the following configuration and application:
- Standby Generators, Prime, Rental that do parallel with each other or the grid
- Diesel, Natural Gas, Propane fueled engines
- 1 Ø 120V / 240V through 3Ø 277V / 480V (347V / 600V CA)
- 4160 through 15KV via PT
- Analog / Hydro Mechanical Engines
Examples include:
- Cummins
- Detector Series
- PCC3100DPC
|
Parallel operation
The ComAp RC3-IG200 or RC3-IG500 is suitable anywhere the RC3-MRS16 fits, but the site needs synchronizing for gen-gen paralleling or gen-mains.
Supports paralleling gen-gen or the grid via external switchgear with Woodward, Barber Colman, Basler, PLC or Cummins devices
|
Gensets with the following configuration and application:
- Standby Generators, Prime, Rental that do NOT parallel with each other or the grid
- Diesel, Natural Gas, Propane fueled engines
- 1 Ø 120V / 240V through 3Ø 277V / 480V (347V / 600V CA)
- 4160 through 15KV via PT
- Analog/ Hydro Mechanical Engines
Examples include:
- Cummins
- PCC3200
- Engines QSX15, QST30, QSK45, 60 & 78
- PCC3201 HM_GCS
- Engines QSX15, QST30, QSK45, 60 & 78
- PCC3201 FAE (ECM)
|
ComAp RCIGNTC
|